Interpretation #7838

Published September 30, 2016

Original Request

Code Version
2014
Code
RESIDENT
Code Description
Chapter
Section
312.2.1
Topic
Window sill height Bldg v Res

Question

Is appears section R312.2.1 of the Florida Building Code - Residential is in conflict with the Florida Building Code - Building section 1013.8.

Answer Published 09/30/2016 at 1:56 PM

It is not uncommon for the provisions for single and two-
family dwellings of the FBC-R to be less stringent than the
FBC-B. It is not a conflict, but a difference between codes.
Due to a specific Exception to the scope of he FBC-B, the FBC-
B does not apply to a single-family residence, unless the
single-family residence is four stories or more. in height.
(s.101.2 Exception 1). In the event the structure is a Group
R-3, the FBC-B applies.

Commentary