Interpretation #6911

Published January 24, 2012

Original Request

Code Version
2007
Code
EXTBLDG
Code Description
Existing Building
Chapter
6
Section
611.1
Topic
re-roofing - Insulation

Question

Is additional insulation required when a condo is to be reroofed?

Answer Published 01/24/2012 at 10:47 AM

No, additional insulation is not required. However, the
existing level (R-value) of insulation must be
replaced or maintained.

Commentary

The "No" applies unless the re-roof qualifies as a renovation as defined in 202. And it seems this is addressed in Section 612. For the purposes of this code, renovation occurs when the first alteration of any wall, ceiling, floor, or other structural part or mechanical system of the building commences, whether or not that alteration affects the external dimensions of the structure.