Interpretation #9569

Published August 14, 2026

Original Request

Code Version
2023
Code
BUILDING
Code Description
Chapter
10
Section
1011.2 Exception: 3
Topic
Stair Chair Lift Encroachment in R2 stair shared by two dwelling units

Question

Does the temporary encroachment created by the chair while it is in motion constitute an obstruction of the required means of egress under the FBC?

Answer Published 08/11/2026 at 3:47 PM

Yes, in accordance with exception 3, the stair encroachment by the chair lift only applies to stairs within the dwelling unit, not the common stairway shared between two dwelling units in an R-2 occupancy. However, if the chair lift was installed within the dwelling unit, the 20-inch clear passage would be measured to the most protruding point of the lift when stationary. in the folded position

Commentary

None.