Interpretation #8428

Published June 26, 2020

Original Request

Code Version
2017
Code
ACCSCODE
Code Description
Chapter
Section
502.1, 502.2, 502.6.1
Topic
Accessible parking spaces

Question

Section 502.6.1 Sates accessible space be prominently outlined with blue paint.
Question 1 Does that mean the blue stripe should be used to define the 12' width required by section 502.1 & 502.2 FBC Accessibility?
Question 2 If the accessible parking space has additional lines outside of the required blue outlining the space, should the additional lines outside of the blue outline be used to define the 12' width of the space?

Answer Published 06/26/2020 at 10:29 AM

Question 1: Per the Federal Access Board Guidelines, the width of the spaces and aisles is measured to the centerline of markings (but it can include the full width of the lines where there is no adjacent parking space of aisles).
Question 2: This would be per the local regulations

Commentary

None.