Interpretation #8334

Published November 12, 2019

Original Request

Code Version
2017
Code
BUILDING
Code Description
Chapter
Chapter 17- Special Inspection and Tests
Section
1709.5.1 exception #1
Topic
Location of Non-Habitable Spaces

Question

Based on Informal Interpretation Report Number 7993, are Business occupancies also considered Habitable spaces? Or are they considered Occupied spaces, per the Definitions in Chapter 2. The below exception would appear to allow doors that meet the design pressures, but not tested for water infiltration, to be used in a commercial environment, without requiring any additional provisions.
1709.5.1, exception 1. Door assemblies installed in nonhabitable areas where the door assembly and area are designed to accept water infiltration need not be tested for water infiltration.
HABITABLE SPACE. A space in a building for living, sleeping, eating or cooking. Bathrooms, toilet rooms, closets, halls, screen enclosures, sunroom Categories I, II, III and IV as defined in Section 2002.6, storage or utility spaces and similar areas are not considered habitable spaces.
OCCUPIABLE SPACE. A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes or in which occupants are engaged at labor, and which is equipped with means of egress and light and ventilation facilities meeting the requirements of this code.

Answer Published 11/12/2019 at 12:44 PM

No, they are not considered habitable spaces as defined by the code. They are occupiable spaces. The Exception cited applies to non-habitable spaces and is not applicable to occupiable spaces. Note the Exception requires the door assembly and the area to be designed to accept water infiltration.

Commentary

This interpretation provides guidance and correction to the previously issued interpretation and should be considered as the current view.