Interpretation #8176

Original Request

  • Date: October 18, 2018
  • Requested By: Tony
  • Requester E-Mail: trex600450@live.com
  • Code Version: 2017
  • Code: MECHANIC
  • Code Description:
  • Chapter:
  • Section: Table 403.3.1.1 Minimum Ventilation Rates
  • Topic: Mechanical Exhaust Ventilation

  • Question: Is mechanical exhaust ventilation required for SFR's that have garages ?

Answer on 10/18/2018 at 9:59 AM

Firstly, the code cited does not apply to SFR. To answer the question, no; unless the blower door test indicates an air infiltration rate of are less than 3 ach thereby triggering a requirement for whole house mechanical ventilation. (FBC-R R303.4)

Commentary:

Refer back to the FBC-Residential, Chapter 15 deals with exhaust systems.