Interpretation #7966

Published September 05, 2017

Original Request

Code Version
2014
Code
PLUMBING
Code Description
Chapter
6
Section
606.1 #6
Topic
Location of full open valves for hotel rooms/

Question

Is it the intent of code section 606.1 #6 to require full open valves at the entrance to each hotel or motel unit if that unit has cooking equipment?

Answer Published 09/05/2017 at 11:11 AM

The intent is to have an individual shutoff for each unit, possibly 2 if both hot and cold are supplied independently.

Commentary

The definitions create some possible confusion with the wording. The intent is clear and also explained in the commentary. typically a branch supply will run the length of the corridor or building and will be tapped for each unit. the supply to each unit should be provided with a shutoff for maintenance purposes within the unit.