Interpretation #7623

Published September 16, 2015

Original Request

Code Version
2014
Code
EXTBLDG
Code Description
Chapter
Section
704
Topic
Window replacement and EERO

Question

Within Chapter 7 of the Existing Building Code 5th Edition, is it the intent of the code to require replacement windows in bedrooms to comply with the requirements of an emergency escape and rescue opening?

Answer Published 09/16/2015 at 11:26 AM

No. Replacement windows serving as EERO may meet the code
in effect at the time of the original construction. In
addition, they may be reduced in size by up to 5%. This was
the subject of Declaratory Statement number DCA07-DEC065.
While the section numbers of the FBC-EC have changed due to
added chapters, the requirements themselves have not changed.

Commentary

None