Interpretation #7622

Published September 16, 2015

Original Request

Code Version
2014
Code
RESIDENT
Code Description
Chapter
Section
322.3.3.1
Topic
Pools in coastal high hazard area

Question

Is it the intent of the "Florida Building Code 322.3.3.1 Pools, which requires pools in coastal high hazard areas to be designed and constructed in conformance with ASCE 24, 9.5 Pools, to require for 9.5 (3), that a pool be in the ground relatively flush with the ground profile at the top of the pool deck?

Answer Published 09/16/2015 at 11:25 AM

No, the pools described would not be considered in the
ground. One concern here is keeping the pool in the ground,
but an increase in the flood elevation in the area caused by
the pool is a large concern as well.

Commentary

See Deemed to Comply Table A in FEMA Guide to ASCE 24, which reads as follows: 9.5 Pools Pools must resist all flood load requirements. If attached to the structure, the pool must act as a continuation of the structure. In V Zones or Coastal A Zones, if the pool is attached to the structure, it must be above the DFE and be elevated per Section 4.4 or be designed to break away during flooding without producing damaging debris. May cause significant cost increases for pools attached to the structure. These are ineligible costs for a HMA project, so pool requirements are the responsibility of the homeowner and must be funded by the homeowner.