Interpretation #7474

Published March 23, 2015

Original Request

Code Version
2007
Code
RESIDENT
Code Description
Residential
Chapter
41
Section
4101.17.1.4
Topic
Pool fence height and climability

Question

This Section indicates... "Where the barrier is composed of

horizontal and vertical members and the distance between

the tops of the horizontal members is less than 45 inches

(1143 mm), the horizontal members shall be located on the

swimming pool side of the fence. Spacing between vertical

members shall not exceed 1 3/4 inches (44 mm) in width." Is it the intent of the code to indicate a 5-foot tri-rail, spear top fence is more climable than a 4' flat top fence?

Answer Published 03/23/2015 at 3:57 PM

The answer is no , the code does not care if it is a 5 ft
tri-rail or a 4 ft flat top, if the fence has both vertical
and horizontal members, and the horizontal members are less
than 45 inches apart, then the horizontal members are to be
on the pool side of the fence, if this occurs the spacing
of the vertical members cannot exceed 1 3/4 inches.

Commentary

The building code section 104.11 allows the building official to make the call, if he deems it an acceptable alternative, meeting the intent.