Interpretation #7421

Published November 05, 2014

Original Request

Code Version
2010
Code
RESIDENT
Code Description
Residential
Chapter
41
Section
4101.17.1.2
Topic
Swimming pool barrier force

Question

Is it the intent of FBC R4101.17.1.2 when indicating "squeeze through" to mean when the design of the fence/barrier has members (pickets) that shall not allow passage of a 4- inch diameter sphere to also address the rigidity of the members so they are not simple flexed allowing a young child to squeeze through?

Answer Published 11/05/2014 at 4:23 PM

Yes.

Commentary

As written in the Code, rigidity is a feature of structural components. "...or structural components..." While we may have regulated common sense out of the majority of the code, if you can push a 4" sphere through it with only a "reasonable" amount of force, it probably does not meet the requirement, whether the picket flexes or not. The Code does not contain specific numeric requirements and we, as an industry, must apply sound reasoning to a requirement such as this. The intent and background of the barrier requirement is to protect children, the elderly and the medically frail from having access to a pool without appropiate supervision. The 4" sphere requirement comes from stairs and guardrails as a way of preventing chidren from getting their heads caught between the ballisters (vertical protection).