Interpretation #7408

Published October 08, 2014

Original Request

Code Version
2010
Code
BUILDING
Code Description
Building
Chapter
6
Section
603.1(2) Excep. 1
Topic
Tile over cork sound insulation

Question

Is it the intent of this code section to be used with ceramic floor tile, cork insulation and a concrete floor slab in type I and II buildings?

Answer Published 10/08/2014 at 10:18 AM

No. As it applies in this situation, section 603.1 (2)
exception 2 would be applicable with a flame spread rating
not to exceed 200, rather than the 100 addressed in
exception 1.

Commentary

Section 805 provides information regarding interior finishes of combustible materials in Type I & II buildings. 805.1.3 addresses insulating boards and allows for materials that are not greater than 1/2" thick covered with finished flooring to be used if in accordance with this section. Based on this, we return to section 603.1 (2) exception 2 for the rating.