Interpretation #7346

Published June 24, 2014

Original Request

Code Version
2010
Code
RESIDENT
Code Description
Residential
Chapter
3
Section
314.3.1
Topic
Smoke Alarms

Question

Is it the intent of 2010 FBC-R 314.3.1 that smoke alarms be addressed if changing out the service panel on the exterior of the building is the only work on the electrical permit?

Answer Published 06/24/2014 at 7:21 PM

No, if all of the work is exterior.

Commentary

It is a well known fact that smoke alarms save lives. One of the exceptions allows for the installation of battery powered alarms, where appropriate. Interconnected battery powered alarms are now available as well. This section of code, while perhaps in the wrong place, it should have been located in the Existing Buildings Volume, is an important life safety section and put in based on changes to Statute, making it law! Whenever work is done, smoke alarms should be installed if they do not exist. While the code may exempt exterior work, we all have a responsibility to life safety and this installation should be encouraged if it is not required.