Interpretation #7327

Published April 14, 2014

Original Request

Code Version
2010
Code
RESIDENT
Code Description
Residential
Chapter
3
Section
R310
Topic
Emergency Egress

Question

Is it the intent of the code that a bathroom window that meets the emergency escape sizes with a bath tub under it be used as a emergency escape window.

Answer Published 04/14/2014 at 6:25 PM

No, the bathroom window may not serve as the emergency
escape and rescue opening. The referenced section
indicates the emergency escape and rescue opening must be
located in the sleeping room not a different room or
an adjoining space or room.

Commentary

Making ones way to the bathroom and negotiating entry through shower curtains or enclosures and into the bathtub, which may provide questionable footing; in order to access the emergency escape opening would be inconsistent with the intent of the referenced section. Additionally, the opening is also for rescue. Firefighters making entry into a bathroom instead of the sleeping room could complicate or compromise their rescue efforts.