Interpretation #7225

Published September 10, 2013

Original Request

Code Version
2010
Code
BUILDING
Code Description
Building
Chapter
4
Section
411
Topic
Amusement Park Attaction

Question

Is it the intent of the code that an amusement park having a 5000 sf bumper car attraction under roof be considered as special amusement per 411 in the Florida Building Code .

Answer Published 09/10/2013 at 8:08 AM

Not necessarily. If the facility meets the definition found
in 411.2, then the answer is yes.

Commentary

The key to the classification is easily and readily identifiable exits. If any system, visual and/or audible, or construction method obstructs the obvious path of exit or hinders the occupants ability to readily discern the exit way and/or exit, then you must meet the requirements of 411.