Interpretation #7195

Published July 07, 2013

Original Request

Code Version
2010
Code
RESIDENT
Code Description
Residential
Chapter
3
Section
R314.3.1, Ex. #2
Topic
Smoke Detectors

Question

Is it the intent of R314.3.1, Ex. #2, that when an electrical permit is required on an existing dwelling unit along with a plumbing and/or mechanical permit for the installation and/or repair of a water heater, whirlpool tub, HVAC system or bathroom exhaust fan, that the smoke detectors do not have to be brought up to the current codes and located as required for new dwellings.

Answer Published 07/07/2013 at 9:36 PM

Yes. The installation, alteration or repair of plumbing or
mechanical systems is exempt from the requirements
of R314.3.1 when an electrical permit is required for the
plumbing or mechanical system installation, alteration or
repair. This is true if the electrical permit is made
necessary by work done to the other systems. However, if the
work involved is an electrical permit only, the upgrade
would be required.

Commentary

None.