Interpretation #6931

Published March 01, 2012

Original Request

Code Version
2007
Code
RESIDENT
Code Description
Residential
Chapter
3
Section
R311.5.6
Topic

Question

Is it the intent of R311.5.6 not allow a 42" height handrail as part of a HVHZ required 42" guardrail for a Single Family Residence spiral stair?

Answer Published 03/01/2012 at 9:36 AM

Yes.
R311.5.6 & R4403.7.3.1 are two separate items.
R 311.5.6 regulates the requirements for handrails.
R4403.7.3.1 regulates the protection of the walking surface
around the opening in the floor or roof. Therefore the
handrail must meet height requirements of 34"-38" measured
from the tread. And the guardrail around the opening in
the floor or roof must meet the height requirements from
the top of the floor or roof surface.

Commentary

See BOAF Informal Interpretation #4454.