Interpretation #6802

Published July 25, 2011

Original Request

Code Version
2007
Code
RESIDENT
Code Description
Residential
Chapter
3
Section
R310.1
Topic
Emergency Escape Discharge

Question

Is it the intent of section R310.1 to prohibit (or to allow) the emergency escape and rescue opening of a residence to open into a neighbor's yard, if that neighbor's yard leads directly to a public way?

Answer Published 07/25/2011 at 9:47 AM

The Scenario as described is NOT allowed by code. The
emergency escape and rescue opening and access to a public
way must be under the control of the property owner,
therefore completely within his/her property.

Commentary

If it is indeed a "Townhouse" the zero lot line wall should not have any openings and should be a fire rated wall. FBCR R302 does not allow a window or door less than 3 feet from the property line.