Interpretation #6608

Published September 01, 2010

Original Request

Code Version
2007
Code
BUILDING
Code Description
Chapter
13
Section
606.AB.1.2.3
Topic

Question

Is it the intent of the Code to allow drywall
joint compound to be used as a "sealant" between
the ceiling gypsum board and the top plate?

Answer Published 09/01/2010 at 6:48 PM

13-606.ABC.1.2.3 Ceilings requires specific location for
application of sealants. Please note this is in the
Residential section of the energy code. The term "sealed"
is not clearly defined in the Energy Code. If done
properly, the sheetrock applied to the roof truss system
would have a sealant applied at each wall intersection. The
local Building Official, generally through the plans
examiner by way of plan review and sign off, must approve
of the methos of sealing as required in the section. The
same requitrement exists in FBC-R Section N1106.AB.1.2.3
without a definition of sealed.

Commentary

This installation would prevent air infiltration from the attic into the wall cavity. Then the wallboard would be installed. The taping and "mudding" of the ceiling and wallboards generally meets the requirement. The exact materials used to accomplish the primarly seal is up to the "approval" of the designer and local Building Official. The process should be as specified on the plans. Another alternative is to install an approved air barrier at the ceiling plane and all penetration of the air barrier shall be made in accordance with the air barrier manufacturer. However, even the air barrier requires a sealant at the exterior walls. Sec. N1106.AB.1.2 , Exterior joints or openings in the envelope, specifies that "Exterior joints, cracks or openings in the building envelope that are sources of air leakage shall be caulked, gasketed, weaterstripped or otherwise sealed in accordance with the criteria in Sec. N1106.AB.1.2.1 through N1106.AB.1.2.5."