Interpretation #6606

Published August 29, 2010

Original Request

Code Version
2004
Code
BUILDING
Code Description
Building
Chapter
4
Section
4.10.5.3
Topic

Question

Is it the intent of section 4.10.5.3 Stage Exits
to require steps which meet the handrail and
width requirements of Chapter 10 at both sides
of the stage?

Answer Published 08/29/2010 at 12:12 PM

Stage areas are usually behind the proscenium wall and a
minimum of two means of egress meeting the width and
handrail requirements are required. The area in front of
the proscenium wall can have stairs that have one handrail
at the wall, unless the stairs are the primary egress from
the stage.

Commentary

This section requires a Means of Egress, compliant with Chapter 10, from each side of the stage behind the proscenium. The steps on the audience side are not intended to be part of the Means of Egress.