Original Request
Request ID:
8571
Requested By:
David Meyer
Requester E-Mail:
davidmeyer@polk-county.net
Code Version:
2021
Code:
RESIDENT
Code Description:
Chapter:
Section:
308.4.5
Topic:
Glazing and wet surfaces
Question:
Would tempered glass still be required with a toilet in front of the window that is less than 60" from waters edge measured horizontally
Comment:
The basic bathroom layout has a window about 24" measured horizontally from the shower edge. There is a toilet in front of window.
Existing Interpretations and/or Declaratory Statements Related to this request
Input Received:
Yes, the code does not recognize the toilet as an acceptable barrier.
Glazing less than 60" horizontally does not meet the exception requirements of 308.4.5.
agree,.
Answer:
Yes, the code does not recognize the toilet as an acceptable barrier.
Edit Answer Text
Yes, the code does not recognize the toilet as an acceptable barrier.
Save Edits
Commentary:
None.
Comments on Draft:
agree
agreed
agree
agree
Publish Draft Interpretation